SCI 발표논문

SCI 발표논문

← SCI 발표논문 목록

Diabetes Care. 2019;42(1):3-9.

The Effect of a Smartphone-Based, Patient-Centered Diabetes Care System in Patients With Type 2 Diabetes: A Randomized, Controlled Trial for 24 Weeks.

, , , , , , , ,

제1저자 김은기 · 교신저자 조영민

PMID 30377185 DOI 10.2337/dc17-2197 IF 22.6 내분비대사내과
소속 (5)
  1. International Healthcare Center, Seoul National University Hospital, Seoul, Korea.
  2. Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Korea.
  3. Department of Internal Medicine, Boramae Medical Center, Seoul, Korea.
  4. Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam, Korea.
  5. Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Korea ymchomd@snu.ac.kr.

Abstract

OBJECTIVE This study evaluated the efficacy of a smartphone-based, patient-centered diabetes care system (mDiabetes) for type 2 diabetes that contains comprehensive modules for glucose monitoring, diet, physical activity, and a clinical decision support system.

RESEARCH DESIGN AND METHODS We conducted a 24-week, multicenter, randomized controlled trial with adult patients with inadequately controlled type 2 diabetes. The patients were randomly assigned to the mDiabetes group or the paper logbook (pLogbook) group. The primary end point was the difference of the change in HbA1c from baseline between the two groups.

RESULTS HbA1c reduction from baseline was greater in the mDiabetes group (-0.40 ± 0.09%, n = 90) than in the pLogbook group (-0.06 ± 0.10%, n = 82). The difference of adjusted mean changes was 0.35% (95% CI 0.14-0.55, P = 0.001). The proportion of patients whose HbA1c fell below 7.0% (53 mmol/mol) was 41.1% for the mDiabetes group and 20.7% for the pLogbook group (odds ratio [OR] 2.01, 95% CI 1.24-3.25, P = 0.003). The percentage of patients who attained HbA1c levels below 7.0% (53 mmol/mol) without hypoglycemia was 31.1% in the mDiabetes group and 17.1% in the pLogbook group (OR 1.82, 95% CI 1.03-3.21, P = 0.024). There was no difference in the event numbers of severe hyperglycemia and hypoglycemia between the two groups.

CONCLUSIONS The implementation of the mDiabetes for patients with inadequately controlled type 2 diabetes resulted in a significant reduction in HbA1c levels, with tolerable safety profiles.

© 2018 by the American Diabetes Association.

Comment · 정정

그 밖의 정보
출판 형태
Journal Article, Multicenter Study, Randomized Controlled Trial, Research Support, Non-U.S. Gov't
저널
Diabetes care · eISSN 1935-5548
전자 출판
2018-10-30
MeSH
Adult · Aged · Aged, 80 and over · Blood Glucose / metabolism · Blood Glucose Self-Monitoring / methods · Body Mass Index · Cholesterol / blood · Diabetes Mellitus, Type 2 / blood / therapy · Female · Glycated Hemoglobin / metabolism · Humans · Hyperglycemia / blood / therapy · Hypoglycemia / blood / therapy · Hypoglycemic Agents / therapeutic use · Insulin / blood / therapeutic use · Male · Middle Aged · Patient-Centered Care* · Pilot Projects · Smartphone* · Triglycerides / blood · Young Adult
Substances
Blood Glucose · Cholesterol · Glycated Hemoglobin · Hypoglycemic Agents · Insulin · Triglycerides
데이터
ClinicalTrials.gov: NCT02451631