SCI 발표논문

SCI 발표논문

← SCI 발표논문 목록

Dig Endosc. 2024;36(4):473-480.

Side-by-side placement of fully covered metal stents versus conventional 7F plastic stents in malignant hilar biliary obstruction: Prospective randomized controlled trial.

, , , , , , , , ,

제1저자 백우현, 정민규 · 교신저자 이상협

PMID 37612129 DOI 10.1111/den.14669 IF 3.6 소화기내과
소속 (10)
  1. Department of Internal Medicine and Liver Research Institute, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
  2. Department of Internal Medicine, School of Medicine, Kyungpook National University, Daegu, Korea.
  3. Department of Internal Medicine, College of Medicine, Pusan National University, Yangsan, Korea.
  4. Biomedical Research Institute, Pusan National University Hospital, Busan, Korea.
  5. Department of Gastroenterology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea.
  6. Department of Gastroenterology, Ajou University School of Medicine, Suwon, Korea.
  7. Department of Internal Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  8. Department of Internal Medicine, Dongguk University Medical Center, Dongguk University College of Medicine, Goyang, Korea.
  9. Department of Internal Medicine, Armed Forces Capital Hospital, Seongnam, Korea.
  10. Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.

Abstract

OBJECTIVES We aimed to evaluate the efficacy and safety of metal stents compared with plastic stents when bilateral side-by-side stents were deployed for malignant hilar biliary obstruction (MHBO).

METHODS Fifty patients with unresectable advanced MHBO were randomly assigned to the metal stent (MS, n = 25) or plastic stent group (PS, n = 25). Fully covered self-expandable metal stents with 6 mm diameter and plastic stents with either 7F straight or double pigtail were used for MS and PS groups, respectively. Time to recurrent biliary obstruction (TRBO) was evaluated as the primary outcome.

RESULTS Both groups had 100% technical success rates; 88% and 76% of clinical success rates were obtained in MS and PS, respectively. Although stent migrations were more frequent in MS than PS (48% vs. 16%, P = 0.02), the mean TRBO was significantly longer in MS (190 days; 95% confidence interval [CI] 121-260 days vs. 96 days; 95% CI 50-141 days, P = 0.02). The placement of plastic stents (hazard ratio 2.42; 95% CI 1.24-4.73; P = 0.01) was the only significant risk factor associated with TRBO in multivariable analysis. The rates of adverse events were similar between the two groups (difference 0%; 95% CI -25% to 25%; P > 0.99).

CONCLUSIONS During bilateral side-by-side deployment in MHBO, the use of metal stents appears to be preferable to plastic stents in terms of TRBO, despite a higher frequency of stent migration.

© 2023 Japan Gastroenterological Endoscopy Society.

Keywords

Klatskincholestasisendoscopic retrograde cholangiopancreatographypalliation

그 밖의 정보
출판 형태
Randomized Controlled Trial, Journal Article
저널
Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society · eISSN 1443-1661
전자 출판
2023-09-21
MeSH
Humans · Prospective Studies · Stents / adverse effects · Cholestasis* / etiology / surgery · Self Expandable Metallic Stents* / adverse effects · Prosthesis Implantation · Treatment Outcome · Retrospective Studies · Bile Duct Neoplasms* / complications / surgery
연구비
Taewoong 0620190860
참고문헌
28편