SCI 발표논문

SCI 발표논문

← SCI 발표논문 목록

Korean J Intern Med. 2021;36(2):332-341.

Progression of ascending aortopathy may not occur after transcatheter aortic valve replacement in severe bicuspid aortic stenosis.

, , , , , , ,

제1저자 정지현 · 교신저자 김형관

소속 (1)
  1. Division of Cardiology, Cardiovascular Center, Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea.

Abstract

BACKGROUND/AIMS We evaluated changes in the ascending aorta dimension post-transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BiAV) and tricuspid aortic valve (TAV) patients.

METHODS Patients with severe aortic stenosis undergoing TAVR at Seoul National University Hospital were consecutively recruited. Patients with less than 12 months' follow-up and/or with an ascending aorta size larger than 50 mm were excluded. The ascending aorta size was measured on a parasternal long axis view using transthoracic echocardiography.

RESULTS Among the 67 patients who were included (age: 76.5 ± 6.5 years; male: 52.2%; AV area: 0.67 ± 0.15 cm2), 19 (28.4%) had BiAV; 48 (71.6%) had TAV. The median (interquartile ranges) follow-up duration was 398 days (361 to 451). BiAV patients were younger (73.2 ± 7.2 vs. 77.8 ± 5.8, p = 0.008), and had lower incidences of chronic renal disease (5.3% vs. 35.4%, p = 0.014) and history of coronary intervention (15.8% vs. 50.0%, p = 0.013), than TAV patients. On pre-procedural echocardiography, the ascending aorta dimensions in BiAV patients were larger than those in TAV patients (40.5 ± 3.8 mm vs. 35.9 ± 4.2 mm, p < 0.005). The ascending aorta dimension changed minimally during follow-up; post-TAVR, the ascending aorta's growth rate was -0.11 ± 1.9 and 0.26 ± 1.8 mm/yr in patients with BiAV and TAV, respectively (p = 0.50). Progression of the ascending aorta's dimension postTAVR was not clinically significant in BiAV patients.

CONCLUSION The concern about the progression of aortopathy in BiAV patients post-TAVR may not be a clinical issue. This should be confirmed in studies with a larger population and with a longer follow-up duration.

Keywords

Aortic aneurysmAortic valve stenosisBicuspidTranscatheter aortic valve replacement

Figures

Figure 1.
Figure 1. Changes in the ascending aorta’s dimension after transcatheter aortic valve replacement. BiAV, bicuspid aortic valve; TAV, tricuspid aortic valve. a p < 0.05 between baseline and 6 months after procedure. b p < 0.05 between baseline and 12 months after procedure. c p < 0.05 between 6 months and 12 months after procedure of ascending aorta’s dimension.
Figure 2.
Figure 2. Growth rates of the ascending aorta’s dimension after transcatheter aortic calve replacement, which were assessed using (A) transthoracic echocardiography (TTE) in all patients and (B) computed tomography angiography (CTA) in 30 patients. The red dots represent patients with a bicuspid aortic valve (BiAV), whereas the blue dots represent patients with a tricuspid aortic valve (TAV). The dashed lines represent the mean values of each group. The growth rates of the ascending aorta in patients with a BiAV showed that there were no significant differences compared with those in patients with a TAV.
Figure 3.
Figure 3. Comparison of the baseline ascending aorta dimension that was measured using transthoracic echocardiography (TTE) and computed tomography angiography (CTA). (A) The correlation between TTE and CTA in the measurement of the ascending aorta’s dimension before transcatheter aortic valve replacement was good. (B) A Bland-Altman plot showed that there was excellent agreement between the two methods.
Figure 4.
Figure 4. Growth rates of the ascending aorta’s dimension according to the baseline ascending aorta size, assessed with (A) transthoracic echocardiography (TTE) and (B) computed tomography angiography (CTA). The red dots represent patients with a bicuspid aortic valve (BiAV), whereas the blue dots represent patients with a tricuspid aortic valve (TAV). The growth rate of the ascending aorta after the procedure cannot be predicted using the baseline ascending aorta dimension

그림 출처: PubMed Central 공개 논문 (PMC7969055)

Conflict of interest statement

No potential conflict of interest relevant to this article was reported.

그 밖의 정보
출판 형태
Journal Article
저널
The Korean journal of internal medicine · eISSN 2005-6648
전자 출판
2019-08-14
MeSH
Aged · Aged, 80 and over · Aortic Valve / diagnostic imaging / surgery · Aortic Valve Stenosis* / diagnostic imaging / etiology / surgery · Heart Valve Diseases* / surgery · Humans · Male · Retrospective Studies · Seoul · Transcatheter Aortic Valve Replacement* / adverse effects
참고문헌
26편