SCI 발표논문

SCI 발표논문

← SCI 발표논문 목록

J Cardiovasc Electrophysiol. 2023;34(9):1811-1819.

Tailored ablation index based on left atrial wall thickness assessed by computed tomography for pulmonary vein isolation in patients with atrial fibrillation.

, , , ,

제1저자 이소령, 박형섭 · 교신저자 최의근, 오세일

PMID 37595097 DOI 10.1111/jce.16026 IF 2.4 순환기내과
소속 (3)
  1. Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
  2. Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea.
  3. Department of Internal Medicine, Division of Cardiology, Dongsan Medical Center, Keimyung University, Daegu, Republic of Korea.

Abstract

INTRODUCTION Although left atrial wall thickness (LAWT) is known to be varied, a fixed target Ablation Index (AI) based pulmonary vein isolation (PVI) has been suggested in catheter ablation for atrial fibrillation (AF). We aimed to evaluate the efficacy and safety of PVI applying tailored AI based on LAWT assessed by cardiac computed tomography (CT).

METHODS The thick segment was defined as the segment including ≥LAWT grade 3 (≥1.5 mm). The fixed AI strategy was defined as AI targets were 450 on the anterior/roof segments and 350 on the posterior/inferior/carina segments regardless of LAWT. The tailored AI strategy consisted of AI increasing the targets to 500 on the anterior/roof segments and to 400 on the posterior/inferior/carina segments when ablating the thick segment. After PVI, acute pulmonary vein (PV) reconnection, defined by the composite of residual potential and early reconnection, was evaluated.

RESULTS A total of 156 patients (paroxysmal AF 72%) were consecutively included (86 for the fixed AI group and 70 for the tailored AI group). The tailored AI group showed a significantly lower rate of segments with acute PV reconnection than the fixed AI group (8% vs. 5%, p = .007). The tailored AI group showed a trend for shorter ablation time for PVI. One-year AF/atrial tachycardia free survival rate was similar in two groups (87.2% in the fixed AI group and 90.0% in the tailored AI group, p = .606).

CONCLUSION Applying tailored AI based on the LAWT was a feasible and effective strategy to reduce acute PV reconnection after PVI.

© 2023 Wiley Periodicals LLC.

Keywords

ablation indexatrial fibrillationleft atrial wall thicknesspulmonary vein isolation

그 밖의 정보
출판 형태
Journal Article, Research Support, Non-U.S. Gov't
저널
Journal of cardiovascular electrophysiology · eISSN 1540-8167
전자 출판
2023-08-18
MeSH
Humans · Atrial Fibrillation* / diagnostic imaging / surgery · Pulmonary Veins* / diagnostic imaging / surgery · Heart Atria / diagnostic imaging / surgery · Tomography, X-Ray Computed · Catheter Ablation* / adverse effects
참고문헌
25편