J Invasive Cardiol. 2012;24(6):270-3.
The efficacy and safety of PRO-kinetic metal alloy stent in hospitalized patients with acute ST-elevation myocardial infarction (The PROMETHEUS Study).
제1저자 임상엽, 박현웅 · 교신저자 연태진
소속 (1)
- Korea University Ansan Hospital, Ansan, Korea.
Abstract
BACKGROUND We evaluated the clinical and angiographic outcomes of silicon carbide-coated cobalt chromium PROKinetic bare-metal stent in patients with acute ST-segment elevation myocardial infarction (STEMI) who underwent primary percutaneous coronary intervention (PCI).
METHODS Patients with acute STEMI (2.75-5.00 mm vessels; lesion length ≤30 mm by visual estimation) were treated with PRO-Kinetic stents at 5 centers in Korea. The primary endpoint was the rate of major adverse cardiac events (MACE), defined as all-cause death, new myocardial infarction, and target lesion revascularization (TLR) at 6-month follow-up. Follow-up angiography was recommended after the completion of the 6-month clinical followup.
RESULTS A total of 64 patients (56.6 ± 12.9 years old, 56 male) were enrolled in the study. Procedural success was achieved in 100% of the lesions. The mean stent size was 3.51 ± 0.67 mm and the mean stent length was 20.3 ± 4.4 mm. There was 1 case of in-hospital death due to cardiac tamponade. During the 6-month clinical follow-up, 4 patients (6.3%) received TLR. Therefore, the total rate of MACE was 7.8%. Angiographic follow-up data were available for 42 patients (65.6%) and the in-stent late lumen loss was 1.02 ± 0.62 mm and in-segment late lumen loss was 0.99 ± 0.64 mm. Binary restenosis occurred in 53% of reference vessel diameters (RVDs) ≤3.0 mm, 25% of RVDs between 3.0 and 3.5 mm, and 0% of RVDs >3.5 mm (P=.006).
CONCLUSIONS The use of the PRO-Kinetic stent seems to be safe and feasible in primary PCI for acute STEMI, and shows favorable clinical and angiographic outcomes in large (>3.0 mm) coronary arteries, but not in small arteries.
그 밖의 정보
- 출판 형태
- Clinical Trial, Journal Article, Multicenter Study, Research Support, Non-U.S. Gov't
- 저널
- The Journal of invasive cardiology · eISSN 1557-2501
- MeSH
- Acute Disease · Adult · Aged · Alloys · Angioplasty, Balloon, Coronary / instrumentation / methods · Carbon Compounds, Inorganic · Chi-Square Distribution · Chromium · Coated Materials, Biocompatible / therapeutic use · Cobalt · Coronary Angiography / methods · Electrocardiography* · Female · Follow-Up Studies · Hospital Mortality / trends · Hospitalization / statistics & numerical data · Humans · Korea · Male · Metals · Middle Aged · Myocardial Infarction / diagnosis / mortality / therapy · Myocardial Revascularization / instrumentation / methods · Prospective Studies · Prosthesis Design · Recurrence · Risk Assessment · Severity of Illness Index · Silicon Compounds · Stents* · Time Factors · Treatment Outcome
- Substances
- Alloys · Carbon Compounds, Inorganic · Coated Materials, Biocompatible · Metals · Silicon Compounds · Chromium · Cobalt · silicon carbide