Int J Cardiol. 2015;184:36-46.
The efficacy and safety of mechanical hemodynamic support in patients undergoing high-risk percutaneous coronary intervention with or without cardiogenic shock: Bayesian approach network meta-analysis of 13 randomized controlled trials.
제1저자 이주명 · 교신저자 김효수
소속 (3)
- Department of Internal Medicine and Cardiovascular Center, Seoul National University Hospital, Seoul, Republic of Korea.
- Department of Internal Medicine and Cardiovascular Center, Boramae Medical Center, Seoul National University, Seoul, Republic of Korea.
- Department of Internal Medicine and Cardiovascular Center, Seoul National University Hospital, Seoul, Republic of Korea; Molecular Medicine & Biopharmaceutical Science, Graduate School of Convergence Science & Technology, Seoul National University, Seoul, Republic of Korea. Electronic address: usahyosoo@gmail.com.
Abstract
BACKGROUND Studies have reported conflicting results regarding efficacy of mechanical hemodynamic support using intra-aortic balloon pump (IABP) or percutaneous ventricular assisted device (pVAD) in patients undergoing high-risk PCI. We performed a Bayesian network meta-analysis comparing the safety and efficacy of mechanical hemodynamic support devices and medical therapy (MT).
METHODS AND RESULTS RCTs comparing overall mortality of IABP versus MT or IABP versus pVAD in high-risk PCI populations were included. The primary endpoint was overall mortality, using the longest available follow-up in each study. This analysis included 2843 patients from 13 trials. In network meta-analysis, overall survival benefit was not significant with IABP (RR 0.84, 95% CrI 0.56-1.24) or pVAD (RR 0.95, 95% CrI 0.42-2.06), compared with MT. IABP or pVAD also did not show early survival benefit compared with MT. In terms of bleeding, pVAD was the worst (versus IABP: RR 29.4, 95% CrI 5.99-221.0; versus MT: RR 41.7, 95% CrI 8.19-330.0), which was mainly driven by the higher incidence of bleeding in the ECMO and TandemHeart, while IABP was worse than MT (RR 1.41, 95% CrI 1.01-2.08). The incidence of acute limb ischemia or vascular complication was not different between treatment groups.
CONCLUSIONS In this meta-analysis, routine elective use of IABP or pVAD did not reduce mortality, while it increased bleeding, compared with MT in high-risk PCI population or even in the patients with cardiogenic shock. Thoughtful selection of appropriate patients and balancing the risk and benefit should be the prerequisites to the use of mechanical hemodynamic support devices.
Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Keywords
Aortic balloon pumpCoronary interventionLeft ventricular assist devicePrimary PCI
그 밖의 정보
- 출판 형태
- Comparative Study, Journal Article, Research Support, Non-U.S. Gov't, Network Meta-Analysis
- 저널
- International journal of cardiology · eISSN 1874-1754
- 전자 출판
- 2015-01-29
- MeSH
- Bayes Theorem · Hemodynamics* · Humans · Intra-Aortic Balloon Pumping / adverse effects / mortality · Patient Safety · Percutaneous Coronary Intervention / adverse effects / mortality · Randomized Controlled Trials as Topic* / methods · Risk Factors · Shock, Cardiogenic / diagnosis / mortality / surgery · Treatment Outcome