SCI 발표논문

SCI 발표논문

← SCI 발표논문 목록

PLoS One. 2023;18(7):e0288421.

Endocardial versus whole-myocardial tracking global longitudinal strain analysis in patients with hypertrophic cardiomyopathy: A preliminary comparative study.

, , , , , , , , , ,

제1저자 박지석 · 교신저자 윤연이, 전은주

소속 (5)
  1. Department of Cardiology, Cardiovascular Center, Seoul National University Bundang Hospital, Seongnam, Gyeonggi-do, Republic of Korea.
  2. Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea.
  3. Department of Radiology, Cardiovascular Center, Seoul National University Bundang Hospital, Seongnam, Gyeonggi-do, Republic of Korea.
  4. Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea.
  5. Department of Internal Medicine and Cardiovascular Center, Seoul National University Hospital, Seoul, Republic of Korea.

Abstract

BACKGROUND AND OBJECTIVES We investigated whether the feasibility of left ventricular (LV) global longitudinal strain (GLS) in hypertrophic cardiomyopathy (HCM) varies according to the methodology (e.g. endocardial vs. whole myocardial tracking techniques).

METHODS We retrospectively analyzed 111 consecutive patients with HCM (median age, 58 years; male, 68.5%) who underwent both transthoracic echocardiography (TTE) and cardiac magnetic resonance imaging (apical 29.7%, septal 33.3%, and diffuse or mixed 37.0%). TTE-whole myocardial and TTE-endocardial GLS were measured and compared in terms of association with late gadolinium enhancement (LGE) extent and discrimination performance for extensive LGE (>15% of the LV myocardium).

RESULTS Although TTE-whole myocardial and TTE-endocardial GLS were significantly correlated, absolute TTE-endocardial GLS values (19.3 [16.2-21.9] %) were higher than TTE-whole myocardial GLS values (13.3[10.9-15.6] %, p<0.001). Both TTE-derived GLS parameters were significantly correlated with the LGE extent and independently associated with extensive LGE (odds ratio [OR] 1.30, p = 0.022; and OR 1.24, p = 0.013, respectively). Discrimination performance for extensive LGE was comparable between TTE-whole myocardial and TTE-endocardial GLS (area under the curve [AUC], 0.747 and 0.754, respectively, pdifference = 0.610). However, among patients with higher LV mass index (>70 g/m2), only TTE-whole myocardial GLS correlated with LGE extent and was independently associated with extensive LGE (OR 1.35, p = 0.042), while TTE-endocardial GLS did not. Additionally, TTE-whole myocardial GLS had better discrimination performance for extensive LGE than TTE-endocardial GLS (AUC, 0.705 and 0.668, respectively, pdifference = 0.006).

CONCLUSION TTE-derived GLS using either the endocardial or whole myocardial tracking technique is feasible in patients with HCM. However, in those with severe hypertrophy, TTE-whole myocardial GLS is better than TTE-endocardial GLS.

Copyright: © 2023 Park et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Figures

Fig 1
Fig 1 Representative case. LV GLS was measured on TTE using whole-myocardial tracking (11.3%) (A) or endocardial tracking (19.9%) (B), and on CMR using TT (6.6%) (C). LGE-CMR revealed extensive LGE, with an LGE extent of 43.0% (D).
Fig 2
Fig 2 GLS values derived from different algorithms and modalities. TTE-endocardial and TTE-whole myocardial GLS values were significantly higher than CMR-TT GLS values. Additionally, TTE-endocardial GLS values were significantly higher than TTE-whole myocardial GLS values.
Fig 3
Fig 3 Correlations between GLS parameters and LVMI and LGE extent. Each GLS parameter demonstrated a significant correlation with LVMI; however, the strongest correlation was obtained with TTE-whole myocardial GLS (A). LGE extent showed a relatively weak, but significant correlation with each GLS parameter (B). However, in the subgroup of patients with high LVMI, CMR-TT GLS and TTE-whole myocardial GLS, but not TTE-endocardial GLS, were significantly correlated with LGE extent (C).
Fig 4
Fig 4 Discrepancies between echocardiographic strain parameters derived from different tracking algorithms. Patients were stratified according to discrepancy between TTE-whole myocardial and TTE-endocardial GLS, using the corresponding optimal cutoff values for detecting extensive LGE (13.0% and 20.5%, respectively). Among the four patient groups, the rate of extensive LGE was highest in Group 4 (concordantly low GLS). Compared to Group 2 (discordantly lower TTE-whole myocardial GLS), Group 3 (discordantly lower TTE-endocardial GLS) showed a higher rate of extensive LGE. Consistent trends were also observed for LGE extent.

그림 출처: PubMed Central 공개 논문 (PMC10335699)

Conflict of interest statement

The authors have declared that no competing interests exist.

그 밖의 정보
출판 형태
Journal Article, Research Support, Non-U.S. Gov't
저널
PloS one · eISSN 1932-6203
전자 출판
2023-07-11
MeSH
Humans · Male · Middle Aged · Contrast Media* · Global Longitudinal Strain · Retrospective Studies · Gadolinium · Myocardium · Cardiomyopathy, Hypertrophic* / diagnostic imaging
Substances
Contrast Media · Gadolinium
참고문헌
25편