SCI 발표논문

SCI 발표논문

← SCI 발표논문 목록

J Am Heart Assoc. 2026;15(2):e045179.

Longitudinal Validation of a Deep Learning Index for Aortic Stenosis Progression.

, , , , , , , , ,

제1저자 박지석, 김지연 · 교신저자 윤연이, 박재형

소속 (6)
  1. Cardiovascular Center and Division of Cardiology, Department of Internal Medicine Seoul National University Bundang Hospital Seongnam Gyeonggi Republic of Korea.
  2. Department of Internal Medicine Seoul National University College of Medicine Seoul Republic of Korea.
  3. Ontact Health Inc. Seoul Republic of Korea.
  4. CONNECT-AI Research Center Yonsei University College of Medicine Seoul Republic of Korea.
  5. Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine Yonsei University Health System Seoul Republic of Korea.
  6. Department of Cardiology, Internal Medicine Chungnam National University Hospital Jung-gu Daejeon Republic of Korea.

Abstract

BACKGROUND Aortic stenosis (AS) is a progressive disease requiring timely monitoring and intervention. While transthoracic echocardiography remains the diagnostic standard, deep learning-based approaches offer the potential for improved disease tracking. This study examined the longitudinal changes in a previously developed deep learning-derived index for AS continuum (DLi-ASc) and assessed its prognostic association with progression to severe AS.

METHODS We retrospectively analyzed 2373 patients (7371 transthoracic echocardiographies) from 2 tertiary hospitals. DLi-ASc (scaled 0-100), derived from parasternal long-axis and short-axis views, was tracked longitudinally. The median follow-up duration was 42.8 (interquartile range, 22.2-75.7) months.

RESULTS DLi-ASc increased in parallel with worsening AS stages (P for trend<0.001) and showed strong correlations with aortic valve maximal velocity (Pearson correlation coefficient, 0.69; P<0.001) and mean pressure gradient (Pearson correlation coefficient, 0.66; P<0.001). Higher baseline DLi-ASc was associated with a faster AS progression rate (P for trend<0.001). Additionally, the annualized change in DLi-ASc, estimated using linear mixed-effect models, correlated strongly with the annualized progression of aortic valve maximal velocity (Pearson correlation coefficient, 0.71, P<0.001) and mean pressure gradient (Pearson correlation coefficient, =0.68; P<0.001). In Fine-Gray competing risk models, baseline DLi-ASc was independently associated with progression to severe AS, even after adjustment for aortic valve maximal velocity or mean pressure gradient (hazard ratios per 10-point increase, 2.38 and 2.80, respectively).

CONCLUSIONS DLi-ASc increased in parallel with AS progression and was independently associated with severe AS progression. These findings support its role as a noninvasive imaging-based digital marker for longitudinal AS monitoring and risk stratification.

Keywords

aortic stenosisartificial intelligenceechocardiographyprogression

그 밖의 정보
출판 형태
Journal Article, Validation Study, Multicenter Study, Research Support, Non-U.S. Gov't
저널
Journal of the American Heart Association · eISSN 2047-9980
전자 출판
2026-01-14
MeSH
Humans · Aortic Valve Stenosis* / physiopathology / diagnostic imaging / diagnosis · Male · Disease Progression · Female · Deep Learning* · Retrospective Studies · Aged · Echocardiography* / methods · Severity of Illness Index · Aortic Valve* / diagnostic imaging / physiopathology · Longitudinal Studies · Prognosis · Middle Aged · Aged, 80 and over · Predictive Value of Tests · Reproducibility of Results · Time Factors