SCI 발표논문

SCI 발표논문

← SCI 발표논문 목록

Europace. 2012;14(8):1104-11.

The anatomical characteristics of three different endocardial lines in the left atrium: evaluation by computed tomography prior to mitral isthmus block attempt.

, , , , , ,

제1저자 조영진, 이활 · 교신저자 오세일

PMID 22417722 DOI 10.1093/europace/eus051 IF 10.2 순환기내과
소속 (1)
  1. Departments of Internal Medicine, Seoul National University College of Medicine and Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul 110-744, Korea.

Abstract

AIMS Additional linear ablation lesions are created to improve the outcomes of pulmonary vein (PV) isolation during atrial fibrillation (AF) ablation. We aimed to evaluate the safety and feasibility of additional ablation sites in terms of anatomical characteristics.

METHODS AND RESULTS Multi-detector computed tomography (MDCT) data from 140 consecutive patients (40 with AF, 84 males, 59 ± 11 years old) and additional 10 heart specimens were analysed for their anatomical characteristics at three types of mitral isthmus lines: anteromedial (AM), anterolateral (AL), and posterolateral (PL) lines (from right superior, left superior, and left inferior PV to 10, 12, and 4 o'clock position of the mitral annulus, respectively). The data demonstrated that the length was shortest at the PL lines (MDCT, 36.4 ± 8.6 mm; specimens, 31 ± 6 mm) and the maximal myocardial thickness was greatest at the AL lines (MDCT, 3.2 ± 1.0 mm; specimens, 5.0 ± 0.9 mm). Ridge, cord-like structure, or diverticulum was found most frequently at the AM lines (MDCT, 20%; specimens, 20%). Sinus nodal artery (SNA) was found near the AM (MDCT, 100%; specimens, 90%) and AL lines (MDCT, 46.3%; specimens, 30%), while left coronary artery (LCA) and cardiac vein were closest to the PL lines. The trend of these findings was not significantly altered with the presence of AF.

CONCLUSIONS The PL lines were shortest among the three mitral isthmus lines, but closest to LCA. Myocardium was thickest at the AL line, and SNAs were frequently found on the anterior lines. Multi-detector computed tomography provided detailed information, and further studies are required to clarify the clinical impact of these findings.

Comment · 정정

그 밖의 정보
출판 형태
Evaluation Study, Journal Article
저널
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · eISSN 1532-2092
전자 출판
2012-03-14
MeSH
Atrial Fibrillation / diagnostic imaging / surgery · Catheter Ablation / methods · Female · Heart Atria / anatomy & histology / diagnostic imaging · Humans · Male · Mitral Valve / diagnostic imaging · Pulmonary Veins / diagnostic imaging · Tomography, X-Ray Computed / methods · Treatment Outcome