Trials. 2013;14:398.
Angiographic and clinical comparison of novel Orsiro Hybrid sirolimus-eluting stents and Resolute Integrity zotarolimus-eluting stents in all-comers with coronary artery disease (ORIENT trial): study protocol for a randomized controlled trial.
제1저자 이주명 · 교신저자 연태진
소속 (1)
- Division of Cardiology, Department of Internal Medicine, College of Medicine, Seoul National University and Cardiovascular Center, Seoul National University Bundang Hospital, 166 Gumi-ro, Bundang-gu, Seongnam-si, Gyeonggi-do 463-707, Republic of Korea. ytjmd@snubh.org.
Abstract
BACKGROUND The Orsiro Hybrid sirolimus-eluting stent is a newly developed third-generation drug-eluting stent, featuring a unique dual-polymer mix. An active bioabsorbable polymer delivers the anti-proliferative drug, sirolimus, via controlled release, while a passive biocompatible polymeric coating shields the metallic strut from surrounding tissue, preventing interaction. To date, the Orsiro Hybrid sirolimus-eluting stent has excelled in terms of late lumen loss at 9 months in a first-in-man single-arm trial. However, the efficacy and safety data for Orsiro Hybrid sirolimus-eluting stents in a broader population of all-comers are limited. The present study offers an angiographic and clinical comparison of the Orsiro Hybrid sirolimus-eluting stent and the Resolute Integrity zotarolimus-eluting stent in the treatment of patients with coronary artery disease.
METHODS/DESIGN The ORIENT trial is a multicenter, randomized, open-label, parallel-arm study designed to demonstrate the non-inferiority of the Orsiro Hybrid sirolimus-eluting stent relative to the Resolute Integrity zotarolimus-eluting stent. A total of 375 patients with a spectrum of coronary artery disease will undergo prospective, random assignment to a Orsiro Hybrid sirolimus-eluting stent or Resolute Integrity zotarolimus-eluting stent (2:1 ratio), for a primary endpoint of in-stent late lumen loss at 9 months by quantitative coronary angiography. Secondary 12-month clinical endpoints are death, target lesion revascularization, target vessel revascularization, myocardial infarction, stent thrombosis and target lesion failure (a composite of cardiac death, target lesion revascularization and target vessel-related myocardial infarction).
DISCUSSION The ORIENT trial is the first study to date comparing the Orsiro Hybrid sirolimus-eluting stent with the Resolute Integrity zotarolimus-eluting stent for efficacy and safety in a population of all-comers with coronary artery disease.
TRIAL REGISTRATION Clinicaltrials.gov NCT01826552.
Figures
그림 출처: PubMed Central 공개 논문 (PMC3842627)
그 밖의 정보
- 출판 형태
- Comparative Study, Journal Article, Multicenter Study, Randomized Controlled Trial, Research Support, Non-U.S. Gov't
- 저널
- Trials · eISSN 1745-6215
- 전자 출판
- 2013-11-20
- MeSH
- Cardiovascular Agents / administration & dosage · Clinical Protocols · Coronary Angiography · Coronary Artery Disease / diagnosis / mortality / therapy · Coronary Restenosis / etiology · Coronary Thrombosis / etiology · Drug-Eluting Stents* · Humans · Myocardial Infarction / etiology · Percutaneous Coronary Intervention / adverse effects / instrumentation / mortality · Prospective Studies · Prosthesis Design · Republic of Korea · Research Design* · Sirolimus / administration & dosage / analogs & derivatives · Time Factors · Treatment Outcome
- Substances
- Cardiovascular Agents · zotarolimus · Sirolimus
- 데이터
- ClinicalTrials.gov: NCT01826552
- 참고문헌
- 20편