SCI 발표논문

SCI 발표논문

← SCI 발표논문 목록

Sci Rep. 2023;13(1):21152.

Association between invasively measured central aortic pulse pressure and diameter of ascending aorta.

, , , , , ,

제1저자 김학령 · 교신저자 김학령

소속 (2)
  1. Division of Cardiology, Department of Internal Medicine, Boramae Medical Center, Seoul National University College of Medicine, 5 Boramae-Ro, Dongjak-Gu, Seoul, 07061, Republic of Korea. khl2876@gmail.com.
  2. Division of Cardiology, Department of Internal Medicine, Boramae Medical Center, Seoul National University College of Medicine, 5 Boramae-Ro, Dongjak-Gu, Seoul, 07061, Republic of Korea.

Abstract

Data on the relationship between arterial pulsatile hemodynamics and aortic root geometry, using invasive hemodynamic measurement, has been scarce. Thus, this study aimed to assess the relationship between invasively measured aortic pulse pressure (aPP) and the diameter of ascending aorta (AoD). We analyzed 665 subjects (64.3 ± 11.0 years; 34.6% female) who underwent elective invasive coronary angiography (ICA) for the evaluation of coronary artery disease. Transthoracic echocardiography was performed on the same day, and AoD was measured at the level of 1 cm above the sinotubular junction at the end-diastole. Body surface area (BSA)-adjusted AoD (AoD/BSA) was used for the analysis. A pig-tail catheter was used to measure aortic pressures at a level approximately 3 cm above the aortic valve just before ICA. aPP was calculated as the difference between systolic and diastolic pressures of the aorta. In multiple linear regression analyses, aPP (β = 0.259; P < 0.001) was found to be significantly correlated with AoD/BSA even after controlling for potential confounders. This correlation power was stronger than aortic systolic pressure (β = 0.189; P < 0.001) and brachial pulse pressure (β = 0.091; P = 0.018) at the same multivariable analyses. In conclusion, our study demonstrated a significant association between invasively measured aPP and AoD/BSA, providing stronger evidence for the link between central aortic pulsatile hemodynamics and aortic root geometry.

© 2023. The Author(s).

Figures

Figure 1
Figure 1 The measurement of the size of ascending aorta by transthoracic echocardiography. The measurement is taken at end-diastole in the parasternal long-axis view, with the size indicated by a red arrow.
Figure 2
Figure 2 Scatter plots showing the associations of AoD/BSA with bPP and aPP. AoD ascending aorta diameter, BSA body surface area, bPP brachial pulse pressure, aPP aortic pulse pressure.

그림 출처: PubMed Central 공개 논문 (PMC10689808)

Conflict of interest statement

The authors declare no competing interests.

그 밖의 정보
출판 형태
Journal Article
저널
Scientific reports · eISSN 2045-2322
전자 출판
2023-11-30
MeSH
Humans · Female · Male · Arterial Pressure* · Aorta, Thoracic · Aorta / diagnostic imaging · Blood Pressure · Coronary Artery Disease*
참고문헌
36편