JACC Cardiovasc Imaging. 2015;8(12):1461-1464.
Real-Time 3D TEE for Diagnosis of Subvalvular Pannus Formation in Mechanical Aortic Valves: Comparison With Multidetector CT and Surgical Findings.
제1저자 이사민 · 교신저자 이승표
소속 (4)
- Cardiovascular Center and Division of Cardiology, Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
- Cardiovascular Center and Division of Cardiology, Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea. Electronic address: splee0624@gmail.com.
- Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea.
- Department of Internal Medicine, Dongguk University Ilsan Hospital, Goyang-si, Gyeonggi-do, Republic of Korea.
Keywords
mechanical aortic valvespannus formationreal-time three-dimensional transesophageal echocardiography
그 밖의 정보
- 출판 형태
- Comparative Study, Journal Article, Research Support, Non-U.S. Gov't
- 저널
- JACC. Cardiovascular imaging · eISSN 1876-7591
- MeSH
- Aged · Aortic Valve / diagnostic imaging / surgery · Bioprosthesis* · Cohort Studies · Echocardiography, Transesophageal / methods · Female · Heart Valve Diseases / diagnostic imaging / surgery · Heart Valve Prosthesis Implantation / adverse effects / methods · Humans · Male · Middle Aged · Multidetector Computed Tomography / methods · Postoperative Complications / diagnostic imaging / physiopathology · Prospective Studies · Prosthesis Failure · Sensitivity and Specificity