SCI 발표논문

SCI 발표논문

← SCI 발표논문 목록

JACC Cardiovasc Interv. 2017;10(8):751-760.

Diagnostic Performance of Resting and Hyperemic Invasive Physiological Indices to Define Myocardial Ischemia: Validation With 13N-Ammonia Positron Emission Tomography.

, , , , , , , , , , , , , ,

제1저자 황도연 · 교신저자 구본권

소속 (8)
  1. Department of Internal Medicine and Cardiovascular Center, Seoul National University Hospital, Seoul, Korea.
  2. Department of Internal Medicine, Sejong General Hospital, Bucheon, Korea.
  3. Division of Cardiology, Department of Internal Medicine, Heart Vascular Stroke Institute, Samsung Medical Center, Seoul, Korea.
  4. China-Japan Union Hospital of Jilin University, China.
  5. Department of Nuclear Medicine, Seoul National University Hospital, Seoul, Korea.
  6. Department of Internal Medicine and Emergency Medical Center, Seoul National University Hospital, Seoul, Korea; Institute of Aging, Seoul National University, Seoul, Korea.
  7. International Centre for Circulatory Health, National Heart and Lung Institute, Imperial College London and Imperial College Healthcare National Health Service Trust, London, United Kingdom.
  8. Department of Internal Medicine and Cardiovascular Center, Seoul National University Hospital, Seoul, Korea; Institute of Aging, Seoul National University, Seoul, Korea. Electronic address: bkkoo@snu.ac.kr.

Abstract

OBJECTIVES The authors sought to compare the diagnostic performance of fractional flow reserve (FFR), instantaneous wave-free ratio (iFR), and resting distal coronary artery pressure/aortic pressure (Pd/Pa) using 13N-ammonia positron emission tomography (PET).

BACKGROUND The diagnostic performance of invasive physiological indices was reported to be different according to the reference to define the presence of myocardial ischemia.

METHODS A total of 115 consecutive patients with left anterior descending artery stenosis who underwent both 13N-ammonia PET and invasive physiological measurement were included. Optimal cutoff values and diagnostic performance of FFR, iFR, and resting Pd/Pa were assessed using PET-derived coronary flow reserve (CFR) and relative flow reserve (RFR) as references. To compare discrimination and reclassification ability, each index was compared with integrated discrimination improvement (IDI) and category-free net reclassification index (NRI).

RESULTS All invasive physiological indices correlated with CFR and RFR (all p values <0.001). The overall diagnostic accuracies of FFR, iFR, and resting Pd/Pa were not different for CFR <2.0 (FFR 69.6%, iFR 73.9%, and resting Pd/Pa 70.4%) and RFR <0.75 (FFR 73.9%, iFR 71.3%, and resting Pd/Pa 74.8%). Discrimination and reclassification abilities of invasive physiological indices were comparable for CFR. For RFR, FFR showed better discrimination and reclassification ability than resting indices (IDI = 0.170 and category-free NRI = 0.971 for iFR; IDI = 0.183 and category-free NRI = 1.058 for resting Pd/Pa; all p values <0.001).

CONCLUSIONS The diagnostic performance of invasive physiological indices showed no differences in the prediction of myocardial ischemia defined by CFR. Using RFR as a reference, FFR showed a better discrimination and reclassification ability than resting indices.

Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Keywords

(13)N-ammonia positron emission tomographycoronary artery diseasefractional flow reserveinstantaneous wave-free ratiomyocardial ischemia

Comment · 정정

그 밖의 정보
출판 형태
Comparative Study, Journal Article, Multicenter Study, Validation Study
저널
JACC. Cardiovascular interventions · eISSN 1876-7605
전자 출판
2017-03-29
MeSH
Aged · Ammonia / administration & dosage · Area Under Curve · Arterial Pressure · Cardiac Catheterization · Coronary Angiography · Coronary Stenosis / diagnostic imaging / physiopathology · Female · Fractional Flow Reserve, Myocardial* · Humans · Hyperemia / physiopathology · Male · Middle Aged · Myocardial Perfusion Imaging / methods / standards · Nitrogen Radioisotopes / administration & dosage · Positron-Emission Tomography* / standards · Predictive Value of Tests · ROC Curve · Radiopharmaceuticals / administration & dosage · Reference Standards · Registries · Reproducibility of Results · Republic of Korea · Severity of Illness Index
Substances
Nitrogen Radioisotopes · Radiopharmaceuticals · Ammonia
연구비
Medical Research Council MR/M018369/1