NPJ Digit Med. 2024;7(1):366.
A prospective comparison of two computer aided detection systems with different false positive rates in colonoscopy.
제1저자 정고은, 이주영 · 교신저자 배정호
소속 (3)
- Department of Internal Medicine and Healthcare Research Institute, Healthcare System Gangnam Center, Seoul National University Hospital, Seoul, Korea.
- Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Korea.
- Department of Internal Medicine and Healthcare Research Institute, Healthcare System Gangnam Center, Seoul National University Hospital, Seoul, Korea. bjh@snuh.org.
Abstract
This study evaluated the impact of differing false positive (FP) rates in two computer-aided detection (CADe) systems on the clinical effectiveness of artificial intelligence (AI)-assisted colonoscopy. The primary outcomes were adenoma detection rate (ADR) and adenomas per colonoscopy (APC). The ADR in the control, system A (3.2% FP rate), and system B (0.6% FP rate) groups were 44.3%, 43.4%, and 50.4%, respectively, with system B showing a significantly higher ADR than the control group. The APC for the control, A, and B groups were 0.75, 0.83, and 0.90, respectively, with system B also showing a higher APC than the control. The non-true lesion resection rates were 23.8%, 29.2%, and 21.3%, with system B having the lowest. The system with lower FP rates demonstrated improved ADR and APC without increasing the resection of non-neoplastic lesions. These findings suggest that higher FP rates negatively affect the clinical performance of AI-assisted colonoscopy.
© 2024. The Author(s).
Figures
그림 출처: PubMed Central 공개 논문 (PMC11659580)
Conflict of interest statement
Competing interests: J.H.B. holds equity in AINEX Corporation. The remining authors declare no competing interests.