J Am Coll Cardiol. 2013;61(5):536-44.
Safety and efficacy of second-generation everolimus-eluting Xience V stents versus zotarolimus-eluting resolute stents in real-world practice: patient-related and stent-related outcomes from the multicenter prospective EXCELLENT and RESOLUTE-Korea registries.
제1저자 박경우 · 교신저자 김효수
소속 (1)
- Department of Internal Medicine and Cardiovascular Center, Seoul National University Hospital, Seoul, Republic of Korea.
Abstract
OBJECTIVES This study sought to compare the safety and efficacy of the Xience V/Promus everolimus-eluting stent (EES) (Abbott Vascular, Temecula, California) with the Endeavor Resolute zotarolimus-eluting stent (ZES-R) (Medtronic Cardiovascular, Santa Rosa, California) in "all-comer" cohorts.
BACKGROUND Only 2 randomized controlled trials have compared these stents.
METHODS The EXCELLENT (Efficacy of Xience/Promus Versus Cypher to Reduce Late Loss After Stenting) and RESOLUTE-Korea registries prospectively enrolled 3,056 patients treated with the EES and 1,998 patients treated with the ZES-R, respectively, without exclusions. Stent-related composite outcomes (target lesion failure [TLF]) and patient-related composite outcomes were compared in crude and propensity score-matched analyses.
RESULTS Of 5,054 patients, 3,830 (75.8%) had off-label indication (2,217 treated with EES and 1,613 treated with ZES-R). The stent-related outcome (82 [2.7%] vs. 58 [2.9%], p = 0.662) and the patient-related outcome (225 [7.4%] vs. 153 [7.7%], p = 0.702) did not differ between EES and ZES-R, respectively, at 1 year, which was corroborated by similar results from the propensity score-matched cohort. The rate of definite or probable stent thrombosis (18 [0.6%] vs. 7 [0.4%], p = 0.306) also was similar. In multivariate analysis, off-label indication was the strongest predictor of TLF (adjusted hazard ratio: 2.882; 95% confidence interval: 1.226 to 6.779; p = 0.015).
CONCLUSIONS In this robust real-world registry with unrestricted use of EES and ZES-R, both stents showed comparable safety and efficacy at 1-year follow-up. Overall incidences of TLF and definite stent thrombosis were low, even in the patients with off-label indication, suggesting excellent safety and efficacy of both types of second-generation drug-eluting stents.
Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
그 밖의 정보
- 출판 형태
- Comparative Study, Journal Article, Multicenter Study, Research Support, Non-U.S. Gov't
- 저널
- Journal of the American College of Cardiology · eISSN 1558-3597
- 전자 출판
- 2012-12-26
- MeSH
- Aged · Cohort Studies · Coronary Thrombosis / epidemiology / prevention & control · Drug-Eluting Stents / adverse effects · Everolimus · Female · Follow-Up Studies · Humans · Korea / epidemiology · Male · Middle Aged · Prospective Studies · Registries · Sirolimus / administration & dosage / adverse effects / analogs & derivatives · Treatment Outcome
- Substances
- Everolimus · zotarolimus · Sirolimus