SCI 발표논문

SCI 발표논문

← SCI 발표논문 목록

J Am Coll Cardiol. 2011;58(18):1844-54.

Everolimus-eluting versus sirolimus-eluting stents in patients undergoing percutaneous coronary intervention: the EXCELLENT (Efficacy of Xience/Promus Versus Cypher to Reduce Late Loss After Stenting) randomized trial.

, , , , , , , , , , , , , , , , , , , , , , , ,

제1저자 박경우 · 교신저자 김효수

소속 (1)
  1. Cardiovascular Center, Seoul National University Main Hospital, Chongno-gu, Seoul, Korea.

Abstract

OBJECTIVES The goal of this study was to compare the angiographic outcomes of everolimus-eluting stents (EES) and sirolimus-eluting stents (SES) in a head-to-head manner.

BACKGROUND EES have been shown to be superior to paclitaxel-eluting stents in inhibiting late loss (LL) and clinical outcome. Whether EES may provide similar angiographic and clinical outcomes compared with SES is undetermined.

METHODS This was a prospective, randomized, open-label, multicenter trial to demonstrate the noninferiority of EES compared with SES in preventing LL at 9 months. A total of 1,443 patients undergoing percutaneous coronary intervention were randomized 3:1 to receive EES or SES. Routine follow-up angiography was recommended at 9 months. The primary endpoint was in-segment LL at 9 months, and major secondary endpoints included in-stent LL at 9 months, target lesion failure, cardiac death, nonfatal myocardial infarction, target lesion revascularization, and stent thrombosis at 12 months. Data were managed by an independent management center, and clinical events were adjudicated by an independent adjudication committee.

RESULTS Clinical follow-up was available in 1,428 patients and angiographic follow-up in 924 patients (1,215 lesions). The primary endpoint of the study (in-segment LL at 9 months) was 0.11 ± 0.38 mm and 0.06 ± 0.36 mm for EES and SES, respectively (p for noninferiority = 0.0382). The in-stent LL was also noninferior (EES 0.19 ± 0.35 mm; SES 0.15 ± 0.34 mm; p for noninferiority = 0.0121). The incidence of clinical endpoints was not statistically different between the 2 groups, including target lesion failure (3.75% vs. 3.05%; p = 0.53) and stent thrombosis (0.37% vs. 0.83%; p = 0.38).

CONCLUSIONS EES were noninferior to SES in inhibition of LL after stenting, which was corroborated by similar rates of clinical outcomes. (Efficacy of Xience/Promus Versus Cypher in Reducing Late Loss After Stenting [EXCELLENT]; NCT00698607).

Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Comment · 정정

그 밖의 정보
출판 형태
Comparative Study, Journal Article, Multicenter Study, Randomized Controlled Trial, Research Support, Non-U.S. Gov't
저널
Journal of the American College of Cardiology · eISSN 1558-3597
MeSH
Aged · Angioplasty, Balloon, Coronary* · Coronary Angiography · Coronary Disease / therapy · Coronary Restenosis / epidemiology · Drug-Eluting Stents* · Everolimus · Humans · Immunosuppressive Agents / administration & dosage · Male · Middle Aged · Prospective Studies · Prosthesis Failure · Sirolimus / administration & dosage / analogs & derivatives
Substances
Immunosuppressive Agents · Everolimus · Sirolimus
데이터
ClinicalTrials.gov: NCT00698607