Korean Circ J. 2024;54(1):13-27.
Risk of Atrial Fibrillation and Adverse Outcomes in Patients With Cardiac Implantable Electronic Devices.
제1저자 이소령, 이지현 · 교신저자 최의근
소속 (7)
- Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea.
- Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Korea.
- Department of Cardiology, Cardiovascular Center, Seoul National University Bundang Hospital, Seongnam, Korea.
- Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Korea. choiek17@snu.ac.kr.
- Medtronic Korea, Ltd., Seoul, Korea.
- Liverpool Centre for Cardiovascular Science, University of Liverpool and Liverpool Chest and Heart Hospital, Liverpool, United Kingdom.
- Department of Clinical Medicine, Aalborg University, Aalborg, Denmark.
Abstract
BACKGROUND AND OBJECTIVES Comprehensive epidemiological data are lacking on the incident atrial fibrillation (AF) in patients with cardiac implantable electronic devices (CIEDs). This study aimed to examine the incidence, risk factors, and AF-related adverse outcomes of patients with CIEDs.
METHODS This was an observational cohort study that analyzed patients without prevalent AF who underwent CIED implantation in 2009-2018 using a Korean nationwide claims database. The subjects were divided into three groups by CIED type and indication: pacemaker (n=21,438), implantable cardioverter defibrillator (ICD)/cardiac resynchronization therapy (CRT) with heart failure (HF) (n=3,450), and ICD for secondary prevention without HF (n=2,146). The incidence of AF, AF-associated predictors, and adverse outcomes were evaluated.
RESULTS During follow-up, the incidence of AF was 4.3, 7.3, and 5.1 per 100 person-years in the pacemaker, ICD/CRT with HF, and ICD without HF cohorts, respectively. Across the three cohorts, older age and valvular heart disease were commonly associated with incident AF. Incident AF was consistently associated with an increased risk of ischemic stroke (3.8-11.4-fold), admission for HF (2.6-10.5-fold), hospitalization for any cause (2.4-2.7-fold), all-cause death (4.1-5.0-fold), and composite outcomes (3.4-5.7-fold). Oral anticoagulation rates were suboptimal in patients with incident AF (pacemaker, 51.3%; ICD/CRT with HF, 51.7%; and ICD without HF, 33.8%, respectively).
CONCLUSIONS A substantial proportion of patients implanted CIED developed newly diagnosed AF. Incident AF was associated with a higher risk of adverse events. The importance of awareness, early detection, and appropriate management of AF in patients with CIED should be emphasized.
Copyright © 2024. The Korean Society of Cardiology.
Keywords
Atrial fibrillationCardiac resynchronization therapyImplantable cardioverter defibrillatorPacemakerRisk factor
Figures
그림 출처: PubMed Central 공개 논문 (PMC10784609)
Comment · 정정
Conflict of interest statement
Eue-Keun Choi reported research grants or speaking fees from Bayer, BMS/Pfizer, Biosense Webster, Chong Kun Dang, Daiichi-Sankyo, Dreamtech Co., Ltd., Medtronic, Samjinpharm, Sanofi-Aventis, Seers Technology, Skylabs, and Yuhan.
그 밖의 정보
- 출판 형태
- Journal Article
- 저널
- Korean circulation journal · ISSN 1738-5520
- 전자 출판
- 2023-09-19
- 연구비
- NIEHS NIH HHS 27302C0028
- 참고문헌
- 25편